SE CONTROLS 'A Day In The Life Of A Smoke Control Maintenance Engineer'

As with all systems in our modern dwellings and offices, they need to be maintained at regular intervals. Maintenance often takes place when there is a failure of a part or parts which then has to be replaced. This approach may be acceptable for general building components, but when we are looking at life - safety systems, ‘preventative maintenance’ is crucial and a legal requirement.

All smoke control systems are maintained on a 6 monthly basis to ensure that all components are fully functional and performs to the original fire design specification for the building by providing continued reliability in the event of a fire. This preventative smoke control maintenance conforms with, BS 9999, BS 7346, Part 1, 1990 and The Building Regulations Approved Document B.

The Regulatory Reform (Fire Safety) Order 2005 (RRO) came into force in 2006; it has changed fire safety requirements and effects all UK organisations. The RRO outlines considerations and requirements for fire safety measures; these include conducting a risk assessment, training, equipment and maintenance.

The writer met up with Steve Birch (an SE Controls Maintenance Engineer) for the day, to visit and help maintain a typical smoke ventilation installation. The objective was to discuss system maintenance and identify typical problems faced by these systems in use.

In apartment buildings it is assumed that a fire is most likely to occur in an apartment. The principle is for the occupant of the apartment which is on fire to escape and the other residents to stay put (they may not even know there is a fire). As the occupant of the ‘fire’ flat escapes, it is probable that some smoke will get into the common corridor or lobby. It is important to ventilate this smoke to prevent it getting in to the common stair and it is the protection of this common stair that is the primary objective. This ventilation also affords some protection to the common corridors/lobbies but this is a secondary benefit – not a primary requirement.

To ventilate this smoke from the corridor or lobby, Approved Document B recommends that if an external window is located on the external wall an Automatic Opening Vent (AOV) can provide effective smoke ventilation. But typically developers are utilising the external wall by adding apartments to create a scenic view for the occupants. In this situation a vertical smoke shaft is provided with either an automatic opening smoke shaft door or damper opening into the smoke shaft and exhausting the smoke into the smoke shaft and out the top of shaft via an AOV.

On each landing or lobby, located on the ceiling is a smoke detector which when activated simultaneously triggers the opening of the corridor or landing AOV, smoke ventilation shaft roof AOV and escape stair AOV. Once opened the system ensures no other doors on the smoke ventilation shaft can be opened ensuring smoke does not transfer between floors.

Testing these systems, the smoke detectors are subjected to smoke tests via a telescopic smoke testing unit each sensor should then operate the corresponding AOVs. This is repeated on each floor after resetting the system. Every twelve months the smoke detectors are cleaned to reduce contamination and false alarms.

To ensure that ‘trap hazards’ are not present when motorised systems are closing, switches adjacent to the AOV need to remain depressed until the doors are fully closed. This configuration is known as a mitigating the risk of the trap hazard to a passing occupant. All AOVs within 2.5 m of floor level must have some form of ‘mitigating procedure’ or safety device fitted and checking these forms part of the inspection.

Following inspection of the system in action, all AOVs, including the doors, windows and roof vents are inspected for signs of wear and tear’ and fixings are checked then lubricated and cleaned if necessary. Any parts requiring replacement are duly noted on a report. Reports are then passed to the managing agents who often look after the building on behalf of the owner. Where failures have occurred during inspection the managing agents would agree a course of repair.

On many installations a repeater panel would be selected to be installed onto a smoke ventilation system. The repeater panel would typically be located near the fire service access entrance of the building to provide system indication.
The repeater panel indicates green lights to show the system as being healthy, a red light shows that the system has been activated in a particular floor or zone and an amber light indicates a fault. Should an amber light or red light remain present on the panel, the maintenance engineer should be called out to undertake a reset or a repair.

Whilst this product is not a requirement under Approved Document B, it is recommended as it provides essential system information for the fire service, client and maintenance engineer.

Within the control panel a 24V battery back-up supply is provided which will continue to operate the smoke ventilation system in the event of a mains supply failure. During maintenance visits batteries are checked for performance and recommended for replacement where they fall below a certain standard. Batteries last on average 3 to 5 years.
So far we have discussed the routine maintenance and repair of systems, but the maintenance engineers’ responsibilities go a little further. Occupiers of a building can often unknowingly influence and compromise the correct working of smoke ventilation systems. One of the most common potential problems is ‘clutter’.

Smoke ventilation stacks are fitted with grills at floor level to ensure safety when the doors are opened. These grilled areas have been used as storage areas by residents. Roof light openings can be compromised by items placed on the roof, on or near to the roof light. Penthouse occupiers can unknowingly cause problems with trees and shrubs which will interrupt the opening of the roof light and could lead to a build up of smoke in an incident. These issues are recorded by the maintenance engineer and again it is up to the managing agents to advise the occupier of the issues and agree a course of action.

As systems become more intelligent and more cost effective to install, cable management and self diagnostic systems are now emerging. Using a much simplified wiring system with less connecting wire, these systems monitor motor speed and resistance to determine the correct operation of the device. Should the ‘load’ profile change, this would indicate a fault and would initiate a call out. SE Controls have developed ‘OSLoop which works on this principle, each zoned area ‘can be linked and where a cable fault or incorrect voltage of the actuation is detected a maintenance engineer can be called to rectify the problem in the particular area. These more advanced systems meet the required standards of the forthcoming EN 12101- 9 and 10, ‘Control Panels and Power Supplies’.

E-mail SE Controls


SE Controls Natural ventilation systems Smoke control systems Window actuators News 081110

Danfoss Heat pumps Speed drives Inverter drives Pressure switches News 081110

Osram Energy efficient lighting Fluorescent lighting Energy saving lighting News 081110

Dimplex Flame effect fires Electric fires Fires and surrounds News 081110

Marley Alutec Rainwater systems Aluminium guttering Drainage systems Aluminium downpipes News 081110

Windhager Gas boilers Energy efficient heating Hot water systems News 081110

Cavalok Cavity closer systems Window closers Cavity fire barriers News 081110

Rockwool Stone wool insulation Insulation products Energy efficient insulation News 081110

Tratos Cable manufacturer Fire resistant cable Fibre optic cable News 081110

Isothane Cavity wall insulation Insulation products External wall insulation News 081110

Rytons Cavity vents Weep holes Building products Ventilation systems News 081110

Slingsby Manual handling equipment Workplace equipment Recycled plastic pallets News 081110

SE Controls Smoke control systems Natural ventilation systems Smoke ventilation News 091110

Danfoss Variable speed drives Low harmonic drives Air conditioning News 091110

Osram LED lighting Osram lighting Light fittings Commercial lighting News 091110

Gilberts Security grilles Air distribution Fire controls Perforated grilles News 091110

 Telling Architectural Rainscreen facades Photovoltaic solar panels Rainscreen cladding systems News 091110

RMIG Aluminium cladding Aluminium panels Perforated metal Acoustic panels News 101110

SE Controls Smoke control systems Smoke detectors Smoke ventilation systems News 101110

Danfoss Cooling systems Water cooling systems Air conditioning systems News 101110

Marshall Tufflex Energy saving units Sub metering systems Energy saving News 101110

Baxi Group Biomass boilers Domestic biomass boilers Wood pellet boilers News 101110

Levolux Solar shading Roller blinds Ventilation louvres Natural ventilation News 101110

Hanson Formpave Concrete block pavers Permeable pavers Permeable block paving News 101110

Window Security Solutions Window shield Window security Vandal shield Glass security News 101110

Oracle Storage systems Wall storage systems Wall filing systems News 101110

SE Controls Automatic window controls Smoke ventilation systems Window automation News 111110

Danfoss Heat pumps Ground heat pumps Ground source pumps News 111110

ENER-G Sustainable energy Data solutions Heat pumps Renewable energy News 111110

Hanson Formpave Block pavers Concrete paving products Permeable block paving News 111110

Isothane Polyurethane coating PU foam Spray foam Industrial foam News 111110

Vent-Axia Ventilation systems Domestic ventilation Natural ventilation Ventilation fans News 111110

Chubb Security Security systems CCTV systems Access control Intruder alarms News 111110

Ellis Furniture Bathroom furniture Bathroom washstands Bathroom worktops Bedroom furniture News 111110

Promat Fire protection systems Passive fire protection Fire protection News 111110

Kalzip Standing seam roofing Low U-value roofing Metal roofing and cladding Solar solutions Green roof systems News 111110

SE Controls Natural ventilation systems School ventilation Commercial ventilation systems News 121110

Hanson Formpave Concrete products Permeable paving Block paving Concrete pavers News 121110

Danfoss Air handling units HVAC drives Variable speed drives News 121110

Coolmation Cooling systems Cooling products Efficient cooling Industrial cooling News 121110

Hanson UK Building materials Cement materials Building aggregates Concrete materials News 121110

Leaderflush Shapland Door sets Metal doors Internal doorsets External doorsets News 121110

Alliance Lighting Aluminium lighting Light fittings Light standards Designer lighting News 121110

Amalgamated Lifts Lift manufacturer Lift maintenance Lift installation Passenger lifts News 121110

Isover Wool insulation Wall insulation Thermal insulation Acoustic insulation News 121110

F Ball and Co Flooring adhesives Waterproof floor membrane Epoxy resin flooring News 121110

Ventrolla Sash windows Window restoration Timber windows Sliding windows News 121110

Gooding Aluminium Aluminium sheets Aluminium profiles Aluminium extrusions Aluminium products News 121110

Schluter-Systems Underfloor heating systems Underfloor heating Radiant flooring heating News 121110

SE Controls Natural ventilation Window automation Solar shading Smoke detection News 151110

Hanson Formpave Concrete products Concrete paving Concrete pavers Permeable paving News 151110

AET Heat pumps Solar panels Air conditioning Flexible space News 151110

Prysmian Cable resin Resin products Electrical cables Power cables News 151110

Armstrong Speed pumps Pump systems Booster pumps Water pumps News 151110

Sunbell Solar shading Light control blinds Remote control blinds News 151110

Forbo Flooring systems School flooring Vinyl flooring Linoleum flooring News 151110

Black Millwork Timber windows Timber doors Patio doors Casement windows News 151110

Knauf Insulation Knauf insulation Carbon management Wool insulation Wall insulation News 151110

Mega Marble Natural stone Natural quartz Marble products Granite products News 151110

Cooper Lighting Commercial lighting Lighting systems Emergency lighting Recessed spotlights News 151110

Cirrus Safety products Noise measurement equipment Sound level meters News 151110

Saint-Gobain Drainage systems Wastewater systems Drainage pipe Commercial drainage News 151110

SE Controls Natural ventilation systems Smoke control systems Window automation News 161110

Dimplex Electric heating Heating products Heat pumps Solar panels News 161110

Crown Trade Trade paint Acrylic eggshell paint Washable matt emulsion News 161110

Weatherite Kitchen ventilation Ventilated ceilings Building services Air conditioning News 161110

Evac Chair Emergency evacuation chairs Evacuation chairs Evac chair training News 161110

Action Storage Storage lockers Storage equipment Plastic lockers Waterproof lockers News 161110

Nuaire Ventilation products Smoke ventilation Ventilation solutions Carpark ventilation News 161110

CMS Acoustics Acoustic panels Sound absorbing panels Acoustic sound panels News 161110

Flowcrete Commercial flooring Resin flooring Floor screed Flooring systems News 171110

SE Controls Natural ventilation systems Smoke control systems Window automation News 171110

Leaderflush Shapland Fire resistant doors Performance doors Fire resistant doorsets News 171110

Twyford Bathrooms Bathroom suites Shower screens Shower trays Bathroom sinks News 171110

Chloride UK Data centre technology Uninterruptible power supplies UPS systems News 171110

Pilkington Building products Energy efficient windows Architectural glass windows News 171110

Action Storage Storage equipment Plastic lockers Waterproof lockers Storage lockers News 171110

Kalzip Standing seam roofing Low U-value roofing Metal roofing and cladding Solar solutions Green roof systems News 171110

Mann McGowan Laminate door boards Fire resistant doors Laminate board News 171110

H+H UK Thermal insulation Wall insulation Celcon blocks Aircrete blocks News 171110

SDS Surface water management Storm water management Drainage systems News 171110

SE Controls Natural ventilation systems Manual window controls Control systems News 181110

Twyford Bathrooms Bathroom shower designs Water saving wc Bathroom suites News 181110

Osram Fluorescent light fittings Energy efficient lighting Light fittings News 181110

Cembrit Fibre cement corrugated sheets Cladding panels Roof slates News 181110

JS Air curtains Warm air curtains Industrial air curtains News 181110

Harlequin Dance floors Performance flooring Ballet barres Vinyl flooring News 181110

Window and Door Security Systems Window security Door security Security systems Window protection News 181110

Playgarden Outdoor play equipment Outdoor play spaces Play equipment News 181110

Sadolin Wood protection Wood stain Sadolin woodstain Wood paint News 191110

Chloride UK UPS power systems UPS systems Uninterruptible power supplies News 191110

Wavin Push fit fittings Flexible plumbing fittings Hep20 fittings News 191110

Harlequin Dance floors Dance mats Studio flooring Dance flooring News 191110

Hitachi Air conditioning units Heat pumps Heating and cooling News 191110

GreenBrook Weatherproof sockets Spur units Electrical sockets Outdoor sockets News 191110

Urban Hygiene School paint Washable paint Protective coatings Graffiti remover News 191110

 

Arundel Jones Associates Ltd Registered in England and Wales No. 07334149
Hill Farm, Linton Hill, Maidstone, Kent ME 17 4AL
Tel : 01622 745333 email
copyright all rights reserved

News Categories : Smoke control systems
Smoke detectors
Smoke ventilation systems